GBCORP BLOG · SUSTAINABILITY

Renewable Energy Glossary: Hydroelectricity, Solar and Wind

Published November 16, 2026 · 8 min read

This renewable energy glossary explains, in plain English, the terms you meet in quotes, datasheets and policy papers. It starts with hydroelectricity, then covers solar, wind, geothermal, storage and the grid, and the measures used to compare projects.

Renewable Energy Glossary: Hydroelectricity, Solar and Wind

Each entry is a short definition you can use straight away. Terms are grouped by technology and run from the basic idea to the detail found in project documents.

Some words, such as reservoir and capacity factor, mean something specific in each section. Figures name their year and come from public agencies such as the US Energy Information Administration (EIA) and Department of Energy (DOE).

Jump to: Hydroelectricity · Solar · Wind · Geothermal · Storage and grid · Markets and measures

Hydroelectricity glossary

Hydroelectricity turns moving water into electricity; in 2025 it supplied about 5.6% of US utility-scale electricity generation and 23.1% of US utility-scale renewable generation.

Head: The vertical drop from the intake to the turbine. The greater the flow and the higher the head, the more electricity a plant can produce.

Flow rate: The volume of water passing through the turbines each second, usually in cubic metres per second. It varies with rainfall, snowmelt and season.

Reservoir (storage) hydro: A plant that stores river water behind a dam and releases it through the turbines when needed, so operators can schedule its output.

Run-of-river: A plant that channels part of a river through a canal or penstock, with little or no storage, so output follows the river. See our hydroelectric energy page.

Pumped-storage hydropower: Water is pumped to an upper reservoir when power is plentiful and released through turbines at peak demand. It is energy storage, not a net source: US plants averaged a round-trip efficiency of 79% in 2019.

Intake: Where water enters the plant, usually with trash racks to keep out debris and gates to shut off the flow.

Penstock: The closed pipe that carries water from the intake down to the turbines.

Pelton turbine: An impulse turbine: free jets of water strike buckets on a wheel spinning in open air. It suits very high heads and low flows.

Francis turbine: A reaction turbine whose runner sits in the water stream and turns under pressure and moving water; common at medium to high heads.

Kaplan turbine: A propeller-type reaction turbine with adjustable blades and wicket gates for a wider operating range, suited to lower heads and larger flows.

Tailrace: The channel that returns water from the turbines to the river.

Spillway: A controlled overflow that lets floodwater pass a dam safely without going through the turbines.

Small hydro: The DOE classes projects of 100 kW to 10 MW as small hydropower and plants above 30 MW as large; other agencies may differ.

Micro hydro: Up to 100 kW under the same DOE definition, typically serving a home, farm or small community.

Capacity factor: Actual output over a period divided by output at full power throughout. In 2025, US utility-scale hydroelectric plants averaged 34.4%, wind 33.8% and solar photovoltaic 24.0%.

Dispatchable (firm) power: Electricity that operators can raise or lower on request. Reservoir hydro is dispatchable; run-of-river, solar and wind follow the weather unless paired with storage.

Solar glossary

These terms cover how sunlight is measured, how panels are rated and how their power reaches a battery, a building or the grid.

Photovoltaic (PV): The direct conversion of light into electricity in a semiconductor, usually silicon. Cells are wired into modules (panels), and modules into arrays.

Irradiance: The power of sunlight on a surface at a given moment, in watts per square metre (W/m²).

Peak sun hours: A day’s solar energy expressed as hours of sunlight at full STC intensity; the quickest way to compare sites and estimate daily output.

Standard test conditions (STC): The rating conditions for panels: 1,000 W/m² irradiance, 25 °C cell temperature and an AM1.5 spectrum. They are rarely met in the field.

kWp (kilowatt-peak): The rated output of a panel or array at STC. It describes system size, not the energy produced, which depends on sunlight, heat and losses.

Temperature coefficient: The percentage of power lost for each degree the cells run above the STC temperature. Cells work best when cool, so a smaller loss per degree is better.

Inverter: Converts direct current (DC) from panels or batteries into alternating current (AC). Grid-connected inverters stop exporting during a grid outage to protect line workers.

MPPT: Maximum power point tracking: electronics that keep adjusting voltage and current to draw the most power from the panels as conditions change.

String: Panels wired in series so their voltages add up. Shade on one panel can pull down the whole string unless optimisers or bypass diodes are fitted.

Bifacial: Panels that also collect light reflected onto their rear face, so the surface beneath and the mounting height affect output.

Thin film: Panels made from very thin light-absorbing layers, mainly cadmium telluride (CdTe) or copper indium gallium selenide (CIGS); on flexible backings they can bend.

BIPV: Building-integrated photovoltaics: PV that forms part of the roof, façade or glazing instead of sitting on top. See our solar energy page.

Net metering: Billing that credits a solar system’s exports to the grid against the electricity the customer imports. Each utility or regulator sets the rules.

Curtailment: A deliberate cut in solar or wind output, through price signals or operator orders, when supply exceeds demand or lines are congested.

Wind glossary

These terms cover when a turbine runs, how large it is and how wind farms are laid out.

Cut-in speed: The wind speed at which a turbine starts generating; the DOE gives about 7–11 mph.

Rated speed: The wind speed at which a turbine reaches full rated power; above it, the blades pitch to hold output steady.

Cut-out speed: The wind speed at which the controller shuts the turbine down to avoid damage; the DOE gives 55–65 mph.

Hub height: The height of the rotor centre above the ground. Taller towers reach stronger winds and capture more energy.

Swept area: The circle the blades cover. Power rises with swept area and with the cube of wind speed, so longer blades and windier sites both pay off.

Capacity factor (wind): Measured as for hydro; US utility-scale wind averaged 33.8% in 2025, and each site depends mainly on its wind resource.

HAWT and VAWT: Horizontal-axis turbines face the wind with a propeller-style rotor and are standard for utility-scale wind. Vertical-axis turbines accept wind from any direction and suit some small sites.

Nacelle: The housing on top of the tower that holds the gearbox, shafts, generator and brake.

Yaw: Turning the nacelle to face the wind, done by a yaw drive powered by yaw motors.

Wake effect: The slower, turbulent air behind a turbine. Wind farms space turbines so downwind machines lose as little output as possible.

Onshore and offshore: Onshore turbines stand on land; offshore turbines stand at sea on fixed or floating foundations, where winds are usually stronger but building costs more.

Geothermal glossary

Geothermal energy is heat from inside the earth, and its power plants run steadily: US utility-scale geothermal plants averaged a capacity factor of 65.9% in 2025.

Geothermal gradient: The rate at which the earth gets hotter with depth. Where it is steep, as in volcanic regions, useful heat is shallower and cheaper to reach.

Geothermal reservoir: Hot rock underground with enough fractures and fluid for hot water or steam to flow to wells.

Dry steam: A plant that uses steam straight from the reservoir to spin the turbine.

Flash steam: A plant that uses high-pressure hot water, part of which turns to steam as the pressure drops; the EIA calls it the most common type.

Binary cycle: A plant that uses geothermal water to boil a second liquid with a lower boiling point, which drives the turbine; the geothermal water never touches it.

Reinjection: Returning cooled geothermal water to the reservoir through injection wells so it can be heated and used again.

Enhanced geothermal system (EGS): A human-made reservoir: fluid is injected under controlled conditions to open fractures in hot rock that lacks natural permeability.

Ground-source heat pump: Heats and cools a building by moving heat to and from the shallow ground through buried pipes; no hot reservoir is needed. See our geothermal energy page.

District heating: Insulated pipes carrying hot water or steam from a central source, such as geothermal wells, to many buildings.

Storage and grid glossary

These terms explain how electricity is stored, moved and kept in balance between supply and demand.

kW and kWh: A kW measures power, the rate of energy flow; a kWh measures energy, one kilowatt for one hour. For a battery, kW says how fast and kWh how much.

Round-trip efficiency: The percentage of electricity put into storage that is later retrieved. In 2019 the US utility-scale battery fleet averaged 82%, and pumped storage 79%.

Depth of discharge: How much of a battery’s capacity is used before recharging. Frequent deep discharges shorten the life of many battery types.

C-rate: Charge or discharge speed relative to a battery’s capacity; higher rates add heat and wear, so follow the datasheet limits.

Baseload: The minimum steady demand on a grid over a period, and the plants that run around the clock to meet it.

Peak load: The highest level of power required over a period, often met by fast-starting plants called peakers or by storage.

Grid frequency: The rate at which alternating current reverses, held close to a fixed national value; it falls when demand outruns supply.

Interconnection: The approved physical and contractual connection of a generator or battery to the grid.

Transmission and distribution: Transmission lines carry high-voltage power over long distances; substation transformers step it down for distribution lines serving homes and businesses.

Microgrid: Interconnected loads and local energy resources within clear electrical boundaries, run as one unit that can connect to the grid or operate in island mode.

Green hydrogen: Hydrogen made by electrolysis, using renewable electricity to split water into hydrogen and oxygen. See our guide to green hydrogen.

Markets and measures glossary

These measures compare projects and technologies on size, cost and emissions.

Nameplate capacity: A generator’s maximum rated output under its manufacturer’s conditions: the size on the label, not its typical output.

Capacity and generation: Capacity is the power a plant can deliver at once (MW); generation is the energy it produces over time (MWh).

LCOE: Levelised cost of electricity: the estimated cost of building and operating a generator over its cost-recovery period, per unit of electricity, usually per MWh.

Power purchase agreement (PPA): A long-term contract to buy a project’s electricity at an agreed price, giving the developer predictable revenue.

Renewable energy certificate (REC): A market-based instrument for the environmental attributes of renewable electricity; one REC is issued per 1 MWh generated and delivered to the grid.

Carbon intensity: Greenhouse gas emitted per unit of electricity, usually in grams of CO2 equivalent per kWh (gCO2/kWh), for a plant or a whole grid.

Lifecycle emissions: Emissions over a plant’s whole life, from materials and construction to operation and decommissioning; the fair basis for comparing technologies.

When these terms turn into a real decision, see GBCORP green energy solutions for the solar products we supply and the renewable-energy projects we deliver. For any installation, follow the equipment manual and your local electrical code, and use a qualified electrician for anything connected to a building’s mains or the grid.

Questions we hear first

What is the difference between kW and kWh?

A kW measures power, how fast energy is used or produced at a moment, while a kWh measures the energy used over time. In the EIA’s example, a 40 W bulb used for five hours uses 200 Wh, or 0.2 kWh.

What does head mean in hydropower?

Head is the vertical drop from the intake to the turbine. More head and more flow both mean more power, and head guides the turbine choice: Pelton for very high heads, Francis for medium to high heads, and Kaplan or other propeller types for lower heads with larger flows.

What is the difference between run-of-river and reservoir hydro?

A reservoir plant stores water behind a dam and releases it when power is needed, so its output can be scheduled. A run-of-river plant diverts part of a river’s flow with little storage, so its output follows the river and the seasons.

What is LCOE?

LCOE, the levelised cost of electricity, spreads the estimated cost of building and running a plant over the electricity it produces during its cost-recovery period, giving a cost per MWh. The EIA pairs it with the value of a plant’s output, because LCOE alone does not capture every factor in an investment decision.

What are peak sun hours in solar energy?

Peak sun hours express a day’s sunlight as the number of hours at the full intensity used to rate panels. Multiplying a panel’s rated output by the peak sun hours gives a rough upper estimate of its daily energy, before losses.